Dayliff DZ self-priming waste water pumps are of semi-open impeller axial flow type designed for pumping water containing high solid levels with particular application for site drainage, sewage and general effluent duties.
FEATURES
- Heavy duty cast iron construction throughout
- pump casting features a suction non return valve, easy opening cleaning ports and mechanical seals
- TEFC non-overloading motor designed for continous operation. Motors should be connected to A DOL starter in accordance with local regulations.
- Enclosure Class: IP56
- Insulation class: F
OPERATING CONDITIONS
Pumped liquid: Thin, chemically non aggressive liquids with a viscosity of up to 50mm 2/s containing suspended solids and particles up to the size indicated.
Working Liquid Temperature: -100C + 800C
Maximum Working Pressure: 6 Bar
Maximum Particle Size: 50mm
PUMP DATA
Model
|
Voltage
(V)
|
Motor
|
Speed
(rpm)
|
Max
Current (A)
|
Dimensions (mm)
|
Weight
(kg)
|
kW
|
HP
|
Intel/Outlet
|
H1
|
H2
|
L
|
W
|
DZ 40-110
|
1x240
|
1.1
|
1.5
|
2900
|
7.2
|
40
|
242
|
168
|
474
|
165
|
57
|
DZ 50-220
|
3x415
|
2.2
|
3.0
|
2900
|
4.9
|
50
|
321
|
201
|
609
|
210
|
75
|
DZ 80-400
|
3x415
|
4.0
|
5.4
|
1450
|
5.1
|
80
|
410
|
310
|
735
|
302
|
121
|