The Dayliff SF range of water softeners are ion exchange type softeners for the removal of hardness in water. The units have been carefully designed to provide the highest levels of performance for all types of domestic, industrial and institutional applications.
Particular features include:
Dayliff SF softeners provide a most effective, reliable and economic solution for all boiler feed and other general softening requirements. The combination of quality components, integrated design and assured Dayliff quality ensures efficient and dependable softeners that can be relied upon to give many years of trouble free operation.
SOFTENER SIZING
Softeners are rated by their exchange capacity, which is the quantity of Calcium that is removable between regenerations and is determined by the resin performance and specified in gms CaCO3. Equipment sizing is then computed on the basis of the raw water hardness and the required brine regeneration period, 24hrs generally being the minimum. An example for sizing an SF600 unit is as follows:-
Exchange Capacity: If resin capacity is 75gms CaCO3 /litre* and resin volume 350litres, = 75x350 = 26,250gms CaCO3
Softening Capacity: Assume water hardness = 300ppm CaCO3 = 26,250/300 = 87.5m³
Flow Rate: Assuming a 20hr operating period/day required flow rate = 87.5/20 = 4.4m³/hr, therefore SF 600 is suitable
Note that softening performance is reduced by increased TDS levels and it is necessary to compute compensated hardness when TDS levels are greater than 400ppm as follows:-
Compensated Hardness (ppm CaCO3) = Measured Hardness (ppm CaCO3) x 9,000 / (9,000 - TDS level(ppm))
Operating Conditions
Raw Water Appearance: Clear
Iron: <0.1ppm
Residual Chlorine: <1ppm
Bacteria: Free
Temperature Range: 5°C- 40° C
Min Inlet Pressure: 1.7 Bar
Max Operating Pressure: (SF-H models) 10 Bar
Max Operating Pressure: (SF models) 3 Bar
EQUIPMENT SPECIFICATION
Model | Resin Volume (Litres) | Exchange Capacity | Softening Capacity (m³) | Rated Service Flow (m³/hr) | Brine Tank Volume (Litres) | Dimensions (mm) | Outlet Sizes (") | Weight (kg) | ||||
100,ppm | 200,ppm | 300,ppm | D | H | Nett | Gross | ||||||
SF 200H | 18 | 1,350 | 14 | 7 | 5 | 2 | 100 | 200 | 900 | 1 | 5 | 20 |
SF 240H | 40 | 3,000 | 30 | 15 | 10 | 2.4 | 200 | 250 | 1,370 | 1 | 15 | 30 |
SF 300 | 50 | 3,750 | 40 | 20 | 13 | 3 | 300 | 300 | 1,450 | 1 | 50 | 90 |
SF 400H | 100 | 7,500 | 75 | 40 | 25 | 5 | 500 | 400 | 1,830 | 1 | 30 | 90 |
SF 500H | 175 | 13,125 | 130 | 65 | 45 | 9.8 | 500 | 550 | 1,770 | 2 | 40 | 150 |
SF 600 | 350 | 26,250 | 260 | 130 | 90 | 9.8 | 600 | 620 | 2,200 | 2 | 100 | 400 |
SF 900 | 750 | 56,250 | 560 | 280 | 190 | 17 | 1,200 | 925 | 2,400 | 2 | 170 | 800 |
SF 900H | 550 | 41,250 | 410 | 205 | 140 | 17 | 1,200 | 930 | 2,150 | 2 | 110 | 580 |
Read More Show Less